Code of Maryland Regulations (Last Updated: April 6, 2021) |
Title 10. Maryland Department of Health |
Part 4. |
Subtitle 34. BOARD OF PHARMACY |
Chapter 10.34.19. Sterile Pharmaceutical Compounding |
Sec. 10.34.19.10. Minimum Requirements for Equipment
-
A. The permit holder shall provide at least the following equipment that is maintained in working order:
(1) Adequate refrigerator and freezer space (if applicable);
(2) A sink and wash area in the anteroom;
(3) Appropriate waste containers for:
(a) Used needles and syringes; and
(b) Cytotoxic waste including disposable apparel used in its preparation, if applicable;
(4) Laminar air flow workstation or compounding aseptic isolator that meets USP 797 Standards, dedicated for products other than antineoplastics;
(5) If applicable to types of preparations compounded, biological safety cabinet, or compounding aseptic isolator that meets USP 797 Standards, dedicated for use with antineoplastics or other hazardous sterile preparations;
(6) Appropriate filters and filtration equipment; and
(7) A device for light/dark field examination.
B. If used, the permit holder shall provide the following equipment that is maintained in working order, calibrated, or certified where appropriate:
(1) Autoclave;
(2) Automated compounding devices (for example, total parenteral nutrition compounding pumps);
(3) Electronic balance;
(4) Convection oven;
(5) Thermometers or other temperature device; and
(6) Incubator.